Detectors  -  Vehicle Options   (MM->5->2)

Hint! - Click on a Vehicle Option to get Help, then return to this screen by typing the "b" key.

<- Det#  Red.Lock  Yel.Lock  Occup  Volum   
     1       .         .       X      X 
     2       .         .       X      X
     3       .         .       X      X
     4       .         .       X      X
     5       .         .       X      X
     6       .         .       X      X
     7       .         .       X      X
     8       .         .       X      X
     9       .         .       X      X
......
    64       .         .       X      X

 

 

 

 

 

 

 

 

 

 

 

NTCIP Object Reference - Detectors - Vehicle Options (MM->5->2)

This menu implements the bitwise data in the NTCIP 1202 object 2.3.2.2 VEHICLE DETECTOR OPTIONS PARAMETER.

Red.Lock 2.3.2.2 Red Lock Call (bit 3) - The Red Lock Calls option allows the detector to lock a call to the assigned phase if the actuation occurs during the red interval.
 
Yel.Lock 2.3.2.2 Yellow Lock Call (bit 2) - The Yellow Lock Calls option allows the detector to lock a call to the assigned phase if the actuation occurs during the yellow interval.
 
Occup 2.3.2.2 Occupancy Detector (bit 1) - The Occupancy Detector option enables the detector to collect occupancy data. Occupancy is the accumulated percentage of time the detector was actuated during the Volume/Occupancy period. The Volume/Occupancy period is set in the Report Parameters.
 
Volum 2.3.2.2 Volume Detector (bit 0) - The Volume Detector option enables the detector to collect volume data. Volume is the accumulated number of actuations during the Volume/Occupancy period. The Volume/Occupancy period is set in the Report Parameters.