Unit, Ring - Ring Sequences (MM->1->2->4)
|
|
Naztec ver 50/60/61 controllers provide 16 sequences (2.8.3 MAXIMUM SEQUENCES) with 1 to 4 rings per sequence (2.8.1 MAXIMUM RINGS). 16 sequence combinations provide every combination of leading and lagging left-turns for an 8 phase, dual ring controller.
Ring sequences and Concurrent Phases (MM->1->1->4) work together the sequencing of the controller. Concurrent phases in separate rings service together, but each ring must terminate together at a "phase barrier" before a new concurrent phase group can be serviced..
The Ring Sequence menu above contains 2 NTCIP objects that are "read-only" values (shown in red) - Seq# (2.8.3.1 SEQUENCE NUMBER) and Ring (2.8.3.2 SEQUENCE RING NUMBER). Up to 8 phases may be assigned to each ring (2.8.3.3 SEQUENCE DATA).