A.9 TIME BASE CONFORMANCE GROUP (NTCIP 1202 ver 2.18)

Links to the menu simulator are provided below for the Parameter objects (P/P2 Object Type).   Parameter objects (highlighted in yellow) are defined in the controller database and can be set by the user through the menus (see A.1.1 TYPE SYMBOLS).  Status objects (S object type) are  "read-only" objects and cannot be changed by the user through the controller menu.  Control objects (C object type) are typically modified by controller hardware inputs or by the signal system (not through the keyboard).

These references are provided to help the user identify each object from the controller menu and are not intended to serve as a compliance statement.  After you click on the link, use the "Page Up" key to move to the controller menu providing access to the object.

Return to the Main Menu

TIME BASE CONFORMANCE GROUP

NTCIP 1201
Clause

Object
Name

Object
Type

Object
Status

Object
Support

Allowed
Values

Supported
Values

2.4

Time Base Conformance Group

--

O

Yes / No

-----

----

2.4.1

globalTme

C

2.4 : M

Yes

counter

 

2.4.2

globalDayLightSavings

P

2.4 : M

Yes

1-19

 

2.4.3

timebase

--

2.4 : M

Yes

----

---

2.4.3.1

maxTimeBaseScheduleEntries

S

2.4 : M

Yes

1-65535

 

2.4.3.2

timeBaseScheduleTable

--

2.4 : M

Yes

---

---

 

timeBaseScheduleEntry

--

2.4 : M

Yes

---

---

2.4.3.2.1

timeBaseScheduleNumber

S

2.4 : M

Yes

1-65535

 

2.4.3.2.2

timeBaseScheduleMonth

P

2.4 : M

Yes

0-65535

 

2.4.3.2.3

timeBaseScheduleDay

P

2.4 : M

Yes

0-255

 

2.4.3.2.4

timeBaseScheduleDate

P

2.4 : M

Yes

0-4294967295

 

2.4.3.2.5

timeBaseScheduleDayPlan

P

2.4 : M

Yes

0-255

 

2.4.3.3

timeBaseScheduleTable-status

S

2.4 : M

Yes

0-65535

 

2.4.4.1

maxDayPlans

S

2.4 : M

Yes

1-255

 

2.4.4.2

maxDayPlanEvents

S

2.4 : M

Yes

1-255

 

2.4.4.3

timeBaseDayPlanTable

--

2.4 : M

Yes

---

---

 

timeBaseDayPlanEntry

--

2.4 : M

Yes

---

---

2.4.4.3.1

dayPlanNumber

S

2.4 : M

Yes

1-255

 

2.4.4.3.2

dayPlanEventNumber

S

2.4 : M

Yes

1-255

 

2.4.4.3.3

dayPlanHour

P

2.4 : M

Yes

0-23

 

2.4.4.3.4

dayPlanMinute

P

2.4 : M

Yes

0-59

 

2.4.4.3.5

dayPlanActionNumberOID

P

2.4 : M

Yes

OID

 

2.4.4.4

dayPlanStatus

S

2.4 : M

Yes

0-255

 

2.4.6

controller-standardTimeZone

P

2.4 : M

Yes

-43200/43200

 

2.4.7

controller-localTime

S

2.4 : M

Yes

counter

 

 

 

 

 

 

 

 

TIME BASE CONFORMANCE GROUP

NTCIP 1202
Clause

Object
Name

Object
Type

Object
Status

Object
Support

Allowed
Values

Supported
Values

2.6

timebaseAsc

--

2.4 : M

Yes

----

---

2.6.1

timebaseAscPatternSync

P

2.4 : M

Yes

0-65535

 

2.6.2

maxTimebaseAscActions

S

2.4 : M

Yes

1-255

 

2.6.3

timebaseAscActionTable

--

2.4 : M

Yes

---

---

 

timebaseAscActionEntry

--

2.4 : M

Yes

---

---

2.6.3.1

timebaseAscActionNumber

S

2.4 : M

Yes

1-255

 

2.6.3.2

timebaseAscPattern

P

2.4 : M

Yes

0-255

 

2.6.3.3

timebaseAscAuxillaryFunction

P

2.4 : M

Yes

0-255

 

 

Bit 0 - Auxiliary 1

--

---

Yes / No

---

---

 

Bit 1 - Auxiliary 2

--

---

Yes / No

---

---

 

Bit 2 - Auxiliary 3

--

---

Yes / No

---

---

 

Bit 3 - Dimming

--

---

Yes / No

---

---

 

Bit 4 - Reserved

--

---

---

---

---

 

Bit 5 - Reserved

--

---

---

---

---

 

Bit 6 - Reserved

--

---

---

---

---

 

Bit 7 - Reserved

--

---

---

---

---

2.6.3.4

timebaseAscSpecialFunction

P

2.4 : M

Yes

0-255

 

 

Bit 0 - Special Function 1

--

---

Yes / No

---

---

 

Bit 1 - Special Function 2

--

---

Yes / No

---

---

 

Bit 2 - Special Function 3

--

---

Yes / No

---

---

 

Bit 3 - Special Function 4

--

---

Yes / No

---

---

 

Bit 4 - Special Function 5

--

---

Yes / No

---

---

 

Bit 5 - Special Function 6

--

---

Yes / No

---

---

 

Bit 6 - Special Function 7

--

---

Yes / No

---

---

 

Bit 7 - Special Function 8

--

---

Yes / No

---

---

2.6.4

timebaseAscActionStatus

S

2.4 : M

Yes

0-255